Cov khoom

2.5MVA Transformer
video
2.5MVA Transformer

2.5MVA Transformer

1. Rated zog: 2.5MVA
2. Thawj qhov ntsuas hluav taws xob: 33KV
3. Secondary Voltage Rating: 415V
4. Zaus: 50Hz lossis 60Hz
5. Tus naj npawb ntawm Theem: Peb
6. Hom Transformer: Roj- raus

Muaj nuj nqi

Baoding Zhongyi Electric Corporation yog ib qho ntawm cov ua lag luam thiab cov muag khoom ntawm 2.5mva transformer hauv Suav teb, tshwj xeeb los ntawm cov khoom zoo thiab cov nqi zoo. Thov so assured mus yuav advanced 2.5mva transformer rau muag ntawm no los ntawm peb lub hoobkas.

 

33KV To 11KV Step Down Power Transformer

Nplooj ntawv no suav nrog ib qho tsim ntawm 2.5 MVA transformer. Roj-immersed, peb-theem, 33 kV ntawm thawj, 415 V ntawm theem nrab. Peb ua nws hauv Baoding, Tuam Tshoj, rau IEC thiab ANSI tsim cov cai. Ob tus lej ntawm nplooj ntawv no txiav txim siab seb nws puas haum rau koj lub network: impedance thiab luv luv - lub zog hluav taws xob. Tshawb xyuas cov no ua ntej koj sib piv cov nqi.

 

Qhov twg siv 33 kV rau 415 V unit

Ib qhov chaw uas twb muaj 33 kV switchgear thiab 415 V faib pawg thawj coj tsis tshua xav tau qhov thib peb qhov hluav taws xob nyob nruab nrab ntawm, thiab qhov sib txawv ntawm ob yog raws nraim qhov no transformer yog tsim los sau.

Muaj cov nroj tsuag uas coj lawv cov khoom ntawm 33 kV thiab faib sab hauv ntawm 415 V, yog li tsis xav tau theem nrab 11 kV.

Cov chaw siv hluav taws xob faib hluav taws xob uas lub 33 kV feeder yuav tsum tau ua haujlwm rau 415 V network hauv zos.

Mines, quarries thiab chaw nres nkoj, qhov twg 33 kV rings yog cov qauv kev coj ua thiab lub chaw thauj khoom nyob deb ntawm qhov chaw nres tsheb loj.

Cov chaw lag luam loj thiab chaw ua haujlwm - cov tsev kho mob, cov chaw khaws ntaub ntawv, cov tsev kawm ntawv qib siab - nrog rau lawv tus kheej 33 kV kev siv.

Cua thiab hnub ci sau cov chaw nres tsheb qhov twg 33 kV yog qhov hluav taws xob array thiab 415 V ua haujlwm pabcuam chaw nres tsheb.

33KV To 11KV Step Down Power Transformer

 

Tshaj tawm specifications

Parameter Tus nqi
Rated zog 2.5 MVA, peb -phase
Thawj qhov voltage 33kv ua
Secondary voltage 415 V
Ntau zaus 50 Hz lossis 60 Hz
Hom Roj-immersed, ONAN txias
Impedance 5%, lossis raws li koj qhov system xav tau
Vector pawg Dyn11, los yog specification
Coj mus rhaub changer Tawm -circuit
Rwb thaiv tsev chav kawm Chav Kawm A
Kub nce Tsawg dua lossis sib npaug li 65℃(65 K hauv IEC cov lus)
Luv- lub zog hluav taws xob 40 kA rau 1 vib nas this
Kev ua tau zoo Ntau dua lossis sib npaug li 97%
Lub suab nrov Tsawg dua lossis sib npaug li 65 dB
Qhov siab Tsawg dua los yog sib npaug li 1000 m
Ambient kub -10℃rau 40 degree
Cov qauv IEC, ANSI

 

 

Khoom Paub meej:
Lub 2.5MVA transformer yog tsim los ua kom tau raws li cov qauv thoob ntiaj teb thiab yog ua los ntawm cov khoom zoo -cov ntaub ntawv zoo uas ua kom muaj kev ruaj khov thiab kev ntseeg tau. Nws nta cov tub ntxhais hlau uas muab cov hlau nplaum tsawg, ua haujlwm tsis muaj suab nrov, thiab qhov tso tawm qhov hluav taws xob ruaj khov. Tsis tas li ntawd, nws muaj kev tsim winding uas ua kom muaj zog hloov pauv tau zoo thiab txo qhov kev pheej hmoo ntawm kev thauj khoom ntau dhau.

2.5MVA Transformer

 

Cov txheej txheem tsim khoom:
Peb 2.5MVA transformers yog tsim los siv cov cuab yeej tshiab thiab khoom siv. Cov txheej txheem ntau lawm suav nrog ntau theem, suav nrog kev tsim, xaiv cov khoom siv, kev sib dhos tseem ceeb, winding, rwb thaiv tsev, thiab kev sim. Peb ua tib zoo saib xyuas kev tswj kom zoo kom ntseeg tau tias txhua qhov transformer uas tawm ntawm peb lub Hoobkas ua tau raws li cov qauv siab tshaj plaws.

2.5MVA Transformer Production Process

 

Dab tsi ships nrog lub tsev, thiab dab tsi tau kuaj

Hom fittings rau cov chav kawm no: conservator, breather, Buchholz relay, siab nyem twj, roj thiab winding kub ntsuas, roj qib ntsuas. Paub meej cov npe tiv thaiv peb cov lus hais, vim hais tias ntxiv qhov haum tom qab raug nqi ntau dua li kev txiav txim tam sim no.

Kev ntsuam xyuas niaj hnub ntawm txhua chav tsev: piv thiab vector pawg, winding resistance, impedance thiab load poob, tsis muaj -load poob thiab tam sim no, rwb thaiv tsev tsis kam, thov thiab induced dielectric xeem, roj dielectric zog, roj noo noo, thiab lub tank xau kuaj.

Hom kev ntsuam xyuas ntawm tus tsim: xob laim impulse thiab kub nce. Ib qho luv luv - ntsuas hluav taws xob tuaj yeem hais qhov twg qhov kev qhia tshwj xeeb xav tau.

Cov neeg yuav khoom pov thawj ntawm cov kev ntsuam xyuas niaj hnub tau txais tos. Hais li ntawd thaum txiav txim theem thiab nws mus rau hauv lub sij hawm xeem.

2.5MVA Transformer

Khoom ntim:
Peb saib xyuas zoo hauv kev ntim peb cov transformers kom ntseeg tau tias lawv xa mus rau peb cov neeg siv khoom zoo meej. Cov transformers tau ntim rau hauv cov ntoo crates thiab npog nrog cov khoom siv tiv thaiv kom tsis txhob muaj kev puas tsuaj thaum thauj khoom.

Packing of the 2.5 MVA transformer for sea freight

Cov lus nug cov neeg yuav khoom nug ntawm qhov ntsuas no

Vim li cas 33 kV thawj es tsis yog 11 kV?
Vim hais tias qhov ntawd yog qhov voltage ntawm qhov khoom tuaj txog. Qhov twg qhov chaw twb khiav lub nplhaib 33 kV los yog siv 33 kV kev sib txuas hluav taws xob, nqis ncaj nraim mus rau 415 V tshem tawm ib qho kev hloov pauv thiab nws cov kev poob. Qhia qhov voltage koj yeej muaj.

Roj- raus lossis qhuav hom ntawm 2.5 MVA?
Cov roj nqi tsawg dua thiab ua haujlwm zoo rau kev ntsuas. Hom qhuav tshem tawm qhov hluav taws kub thiab qhov teeb meem ntawm qhov ntim, uas yog qhov tseem ceeb hauv tsev. Sab nraum zoov, roj feem ntau yeej. Hauv ib lub tsev nrog cov cai nruj, hom qhuav feem ntau ua.

5% impedance txhais li cas rau peb LV tiv thaiv?
Nws teeb tsa qhov txhaum tam sim no LV switchgear yuav tsum cuam tshuam: kwv yees li 70 kA ntawm qhov thib ob terminals ntawm qhov ntsuas no, ua ntej qhov impedance ntxiv. Breaker rating thiab kev ntxub ntxaug kev kawm yog ob qho tib si tsim los ntawm tus lej ntawd, thiab hloov qhov impedance tom qab txhais tau tias rov ua txoj kev tshawb no.

Nws puas tuaj yeem khiav ntawm 45℃ambient lossis ntawm 1800 m qhov siab?
Yog, nrog ib tug derated tsim. Xa cov xwm txheej ntawm qhov chaw nrog cov lus nug thiab qhov derate tau teev nyob rau hauv cov lus hais.

Lub suab nrov tuaj yeem qis dua 65 dB?
Feem ntau yog, thiab nws tau hais ntau dua li tau cog lus tseg. Qhia peb txog qhov txwv thiab qhov ntsuas qhov deb koj tus qauv siv.

Koj puas tsim tib qhov kev ntsuas rau 60 Hz?
Yog lawm. Flux ceev thiab txias yog kho rau 60 Hz ua haujlwm.

 

Ordering 2.5 MVA transformer pib nrog ib daim ntawv luv luv zoo li qhov ntawd. Xa nws thiab koj yuav tau txais daim duab kos duab dav dav, nyiaj txiag poob, roj kom muaj nuj nqis thiab hnub xa khoom koj tuaj yeem npaj ib puag ncig.

Cim npe nrov: 2.5mva transformer, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, yuav, nqi, kev muag khoom

Koj Tseem Yuav Zoo Li

(0/10)

clearall