Cov khoom
1 MVA 11KV rau 415V Kauj Ruam Tshaj Tawm Transformer
1. Rated zog: 1 MVA
2. Rated Voltage High Sab (HV): 11 kV
3. Rated Voltage Tsawg Sab (LV): 415 V
4. Zaus: 50 Hz
5. Vector Group: Dyn11
Muaj nuj nqi
1 MVA 11KV rau 415V Kauj Ruam Down Distribution Transformer Specification:
1. Rated zog: 1 MVA
2. Rated Voltage High Sab (HV): 11 kV
3. Rated Voltage Tsawg Sab (LV): 415 V
4. Zaus: 50 Hz
5. Cua txias hom: ONAN (Oil Natural Air Natural)
6. Vector Group: Dyn11
7. Coj mus rhaub Changer: Tawm Circuit Court
8. Cov Qauv: IEC 6007
9. Kev ua tau zoo: Tsis pub tsawg dua 99 feem pua
10. Rwb thaiv tsev: Chav A
11. Ambient Kub: 40 degree
12. impedance: 6 feem pua
13. Cov khoom siv winding: tooj liab
14. Zuag qhia tag nrho Dimensions: Raws li ib daim duab
15. Nyhav: Raws li kev kos duab
Nco tseg: Cov lus qhia saum toj no yog qhov qhia tau thiab tuaj yeem ua raws li cov kev xav tau tshwj xeeb.

1 MVA 11KV rau 415V Kauj Ruam Down Distribution Transformer Accessories:
1. Bushings: Cov no yog cov khoom siv hluav taws xob uas txuas rau lub tshuab hluav taws xob, tsis hais nyob rau sab high-voltage lossis low-voltage sab, mus rau cov nyiaj siv ua haujlwm lossis cables. Muaj ntau hom bushings muaj, xws li porcelain, resin, thiab composite, nyob ntawm daim ntawv thov thiab ib puag ncig.
2. Txias System: Lub tshuab hloov hluav taws xob tsim hluav taws xob thaum lub sijhawm ua haujlwm, thiab cov cua sov no yuav tsum tau dissipated los tiv thaiv cov khoom puas. Cov tshuab cua txias xws li radiators, kiv cua, roj twj, thiab cov cua txias yog siv los ua kom lub tshuab hloov pauv qhov kub thiab txias tsis pub dhau kev txwv.
3. Coj mus rhaub Changer: Raws li lub npe qhia, cov khoom siv no tso cai rau lub tshuab hluav taws xob tso zis hluav taws xob hloov kho los ntawm kev hloov cov lej hloov ntawm qhov thib ob winding. Kais changers feem ntau yog ob hom: on-load thiab off-load, thiab xaiv hom nyob ntawm daim ntawv thov.
4. Cov khoom siv tiv thaiv: Cov no suav nrog cov khoom siv xws li fuses, Circuit Court breakers, thiab relays, uas yog ntsia los tiv thaiv lub transformer los ntawm overloads, luv Circuit Court, thiab lwm yam txhaum. Cov cuab yeej no pab tiv thaiv lub transformer thiab tiv thaiv kev puas tsuaj rau cov khoom siv.
5. Cov cuab yeej saib xyuas: Ntau yam kev soj ntsuam cov cuab yeej xws li ntsuas kub ntsuas, ntsuas roj qib ntsuas, thiab ntsuas ntsuas siab tau teeb tsa los muab cov ntaub ntawv hais txog lub tshuab hloov pauv kev ua haujlwm. Cov ntaub ntawv no yog siv los txheeb xyuas cov teeb meem uas yuav tshwm sim thiab kho kom raug ua ntej muaj kev puas tsuaj.
1 MVA 11KV rau 415V Kauj Ruam Tshaj Tawm Transformer Ntim Thiab Shipping:
1MVA 11KV rau 415V Kauj Ruam Down Distribution Transformer yog cov khoom siv hnyav hnyav uas yuav tsum tau tuav tshwj xeeb thiab ntim kom ntseeg tau tias nws muaj kev nyab xeeb kev thauj mus los rau nws qhov chaw. Nov yog cov kauj ruam feem ntau ua raws li kev ntim khoom thiab xa khoom:
1. Kev ntxuav thiab tshuaj xyuas: Ua ntej ntim, lub tshuab hloov pauv tau raug ntxuav kom huv si thiab tshuaj xyuas kom ntseeg tau tias nws nyob hauv kev ua haujlwm zoo thiab tsis muaj khawb lossis puas tsuaj.
2. Disassembly: Nyob ntawm tus tsim ntawm lub transformer, qee qhov yuav tsum tau disassembled ua ntej ntim. Qhov no yog los xyuas kom meej tias cov khoom muaj kev ruaj ntseg zoo thiab yuav tsis txav mus los thaum caij tsheb thauj mus los.
3. Cov Khoom Siv Ntim: Cov khoom ntim khoom siv rau lub tshuab hloov pauv feem ntau yog cov ntoo crate uas tshwj xeeb tsim los tswj qhov hnyav thiab qhov loj ntawm cov khoom siv. Lub crate yog lined nrog ua npuas ncauj thiab cushioning cov ntaub ntawv los tiv thaiv lub transformer los ntawm tej shocks los yog pob thaum lub sij hawm kev thauj mus los.
4. Kev ruaj ntseg ntawm Transformer: Lub transformer yog ruaj ntseg fastened mus rau hauv qab ntawm lub crate siv bolts thiab straps. Ntxiv ua npuas ncauj padding yog siv nruab nrab ntawm lub transformer thiab lub crate los tiv thaiv kev txav thaum lub sij hawm xa khoom.
5. Cov ntawv sau npe thiab cov ntaub ntawv: Lub crate yog sau nrog cov ntaub ntawv xa khoom tsim nyog, suav nrog tus neeg txais lub npe thiab chaw nyob, qhov hnyav thauj khoom, thiab cov lus ceeb toom lossis kev qhia txog kev fragility. Tsis tas li ntawd, tag nrho cov ntaub ntawv xa khoom tsim nyog, xws li cov nqi thauj khoom thiab cov ntaub ntawv kev lis kev cai, tau npaj thiab suav nrog cov khoom xa tuaj.
6. Shipping: Nyob ntawm qhov chaw, lub transformer yuav raug xa los ntawm lub tsheb, tsheb ciav hlau, lossis nkoj. Lub tuam txhab thauj khoom yog lub luag haujlwm los xyuas kom meej tias lub tshuab hloov pauv tau ua haujlwm zoo thiab xa mus rau nws qhov chaw raws sijhawm thiab nyob rau hauv qhov zoo.
Zuag qhia tag nrho, kev ntim khoom thiab xa tawm 1MVA 11KV rau 415V Kauj Ruam Down Distribution Transformer yuav tsum tau ua tib zoo npaj, ua tib zoo saib xyuas kom meej, thiab kev koom tes ntawm txhua tus neeg koom tes los xyuas kom meej tias cov cuab yeej tuaj txog ntawm nws qhov chaw nyab xeeb thiab tsis muaj kev puas tsuaj.

FAQ:
1.Lub Transformer puas siv fais fab tsis muaj Load?
Tsis yog, lub tshuab hluav taws xob tsis siv lub zog thaum tsis muaj kev thauj khoom txuas nrog nws cov winding thib ob. Nyob rau hauv ib qho zoo tagnrho transformer, tsis muaj qhov poob ntawm lub zog vim qhov tsis muaj kev thauj khoom ntawm cov khoom siv thib ob. Txawm li cas los xij, nyob rau hauv lub ntiaj teb tiag transformers, tej zaum yuav muaj qee qhov kev poob qis vim yog yam xws li kev ua haujlwm thiab kev xau inductance. Cov kev poob no feem ntau me me thiab tsis pom zoo piv rau lub zog siv los ntawm kev thauj khoom.
2.Yuav ua li cas mus yuav 1 mva 11kv rau 415v kauj ruam nqes faib transformer?
1. Txiav txim siab koj qhov yuav tsum tau ua: Koj yuav tsum txiav txim siab qhov voltage thiab lub zog ntawm koj daim ntawv thov. Nyob rau hauv cov ntaub ntawv no, koj xav tau ib tug step-down transformer uas muaj peev xwm muab 1 MVA fais fab tso zis thiab yuav hloov 11kV rau 415V.
2. Xaiv hom transformer: Muaj ntau hom transformers muaj nyob rau hauv kev ua lag luam, xws li roj-immersed, qhuav-hom, thiab cam khwb cia resin transformers. Xaiv hom uas haum koj xav tau.
3. Nrhiav tus neeg muag khoom muaj npe nrov: Tshawb nrhiav tus neeg muag khoom muaj npe nrov uas tuaj yeem muab koj lub tshuab hloov pauv zoo. Tshawb nrhiav cov neeg muag khoom uas muaj cov ntaub ntawv pov thawj ntawm kev tsim cov khoom siv hluav taws xob rau cov lus qhia tshwj xeeb.
4. Xav txog tus nqi: Thaum koj tau txheeb xyuas cov neeg xa khoom muaj peev xwm, sib piv cov nqi ntawm cov transformers. Nco ntsoov tias koj muaj lwm yam nqi xws li kev thauj mus los, kev teeb tsa, thiab kev ua haujlwm.
5. Tshawb xyuas qhov kev lees paub thiab kev pabcuam: Ua ntej ua qhov kev yuav khoom zaum kawg, tshawb xyuas qhov kev lees paub thiab kev pabcuam los ntawm tus neeg muag khoom. Xaiv ib tus neeg muag khoom uas muab lub sijhawm lav zoo thiab muaj pab pawg pab cuam tom qab muag zoo.
Nco ntsoov ua haujlwm nrog ib tus kws kho hluav taws xob tsim nyog thiab ua raws li cov qauv kev nyab xeeb thaum txhim kho cov khoom siv hluav taws xob.
Cim npe nrov: 1 mva 11kv rau 415v kauj ruam down faib transformer, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, yuav, nqe, kev muag khoom
Koj Tseem Yuav Zoo Li
Ntau35KV Peb Theem Roj Txias Distribution Transformer
NtauSab Hauv Tsev Roj Hom Hluav Taws Xob Transformer
Ntau3 Theem Roj Sau Tus Kheej Txias Hom Transformer
Ntau250 KVA Ncej Mounted Distribution Transformer
Ntau3 MVA 3000 KVA 11kV Roj Txias Distribution Transformer
Ntau2 00 KVA 11kV 6.6kV 0.4kV Dual Voltage Distribution ...
Xa kev nug